Philips Brilliance CT 64-channel with Essence technology. 2 Table of contents 1 Essence technology 3 1.1 X-ray Tube features 3. Manual longitudinal stroke, mm 1900 mm Scannable range, mm 1750 mm Z-position accuracy ±0.25 mm Longitudinal speed, mm/s 0.5 – 143 mm/s.
The Philips Brilliance 16 CT scanner is fast enough to measure up against many more expensive systems, and the Brilliance Workplace system is widely acclaimed as one of the most efficient and user-friendly. So both your operators and your patients will appreciate the speed of this system, and its image quality will allow you to make a diagnosis. Asio4all mac driver download. Philips CT Scanners Comparison Chart. Model: Brilliance iCT: Brilliance 16-slice MX 16-slice: Ingenuity CT: Brilliance 64-channel.
Philips Brilliance Ct User Manual
- Documents
- Videos
- News
DESCRIPTION
Philips Brilliance Ct Manual
Outstanding performance is routineThe Brilliance CT 16-slice configuration is a complete, high-performance system ideally suited to routine CT studies, CTA, and advanced motion-sensitive applications such as CT colonography and pulmonary studies.
With fast reconstruction and a range of automated tools to set up patients and manage scans, Brilliance CT 16-slice can help you make the most of each day. The system also includes a range of thoughtful features to help maximize dose efficiency.
FORUMSView All (16)
Philips Brilliance 16 Slice Ct Manual
Ask a New QuestionPhilips Brilliance Ct Manual Instructions
5Replies4 months ago | 4 months agoGantry turns off Hello,The gantry is shutting off a few seconds after key is turned on upon bootup. Sounds like a contactor turns off. Any ideas? Going to take a first in the morning.Reply |
-Wilver 5 months ago | 5 months agoService manual How to get service manual?Reply |
2Repliesa year ago | a year agoerror gantry have problem with ct Phillips brilliance 16 slice: when I trying turn on the sytem from the key it0019s not start. Gantry is rotate but its not parking and leds on the gantry not turn on. When i turn on the key i see Errors in viewer: s_rmc__error_mcoS rms sb faultS rms mp dth bad paramS rmc dth bad paramS rotor dth bad params collision bad dth paramMay be its spindle block fault?Can you help me?Reply |
FEATURES
- High-quality imaging, fast reconstruction, task automation, and evolved ways to minimize radiation dose
- Scan times of 0.4 sec* full gantry rotation, temporal resolution as low as 53 msec, and reconstruction rates of up to 20 ips*
- Rate Responsive* technology for advanced cardiac imaging, including calcium scoring, as well as retrospective and prospective gating
- Patented MRC X-ray tube to provide necessary heat capacity for longer scan times, enabling thin-slice imaging
- Spiral Auto Start*, which allows you to monitor contrast injections and initiate and stop scans without having to leave the scan room
- Philips DoseWise approach for optimal dose efficiency to help protect your patients without compromising image quality
- The only CT user environment developed especially for multislice CT
- Comprehensive support for you in every season of system ownership
SPECIFICATIONS
Gantry (Max. Clearance) | 70 cm |
Image Display | 18 in flat LCD 4 |
Maximum Scan Range | 175 cm |
Patient Weight Capacity | 450 lbs |
Slices | 16 |
Type (configuration) | Multislice |
Additional Specifications
Philips Brilliance 16 Ct Scanner Manual
Configuration:
8.0 MHU MRC X-ray tube
60 kW Generator
0.5 sec Rotation (0.4 sec optional)
16 x 0.75mm, 16 x 1.5mm, 8 x 3mm, 4 x 4.5mm, 2 x 0.6mm
6 ips standard reconstruction (20 ips optional)
24 Lp/cm resolution
Brilliance Workspace